Occupational Hygiene Monitoring Survey Report

Cold Stress Survey Report

Client · Site

02 Sept 2026

Project Number — · Revision 0

Survey Information Details

Report NumberOH-2026-000-R0
Project Number—
Client—
Site / Premises—
Physical Address—
Survey Date02 Sept 2026
Stress FactorCold Stress — Equivalent Chill Temperature
Surveyor—
Technical SignatoryRiaan de Villiers
Applicable LegislationPhysical Agents Regulations, 2024 · Environmental Regulations For Workplaces, 1987
Occupational Exposure LimitFour-Hour TWA ECT Cold-Stress TWA-OEL 10 °C · ERW Criterion 6 °C

1.0 Executive Summary

The client contracted The Safety Network (Africa) (Pty) Ltd to conduct a cold stress survey at the premises, . The survey was conducted on 02 Sept 2026 by —.

The outdoor four-hour TWA ECT remained above the cold-stress TWA-OEL of 10 °C. The chill room exposure fell below the OEL and requires the minimum controls of Regulation 9(2).

2.0 Purpose Of The Survey

  1. Assess cold stress exposure of employees performing outdoor or refrigerated work
  2. Measure dry-bulb temperature and air velocity at representative positions
  3. Calculate the four-hour TWA Equivalent Chill Temperature
  4. Recommend cold stress control measures where required

3.0 Contents Of Report

  1. 1.0Executive Summary
  2. 2.0Table Of Contents
  3. 3.0List Of Tables, Figures And Diagrams
  4. 4.0List Of Terms And Abbreviations
  5. 5.0Introduction
  6. 6.0Monitoring Methods And Procedure Followed
  7. 7.0Results And Discussion
  8. 8.0Recommendations
  9. 9.0Conclusion
  10. 10.0Indemnity And Signatures
  11. 11.0References
  12. 12.0Annexures To The Report

4.0 Instruments Used

InstrumentSerial NumberCalibration Due
Gilian 5000 pumpGIL-440204 Nov 2026
Gilian 5000 pumpGIL-440722 Oct 2026
SKC Airchek TOUCHSKC-221027 Sept 2026

5.0 Results And Discussion

PositionAreaPeriodDry Bulb °CAir Velocity m/sECT °COEL Exceeded
C-01Outdoor Loading Bay08:00 — 12:0013.71.213.7No
C-02Chill Room08:00 — 12:004.50.82.9Yes

The outdoor four-hour TWA ECT remained above the cold-stress TWA-OEL of 10 °C. The chill room exposure fell below the OEL and requires the minimum controls of Regulation 9(2).

6.0 Recommendations

  1. Maintain issued cold weather protective clothing
  2. Apply warm-up breaks for chill room work
  3. Address cold stress in the physical agent exposure risk assessment
  4. Re-assess during the coldest month of the year

7.0 Conclusion

Cold stress is controlled outdoors. Chill room work requires the prescribed minimum cold-stress controls.

8.0 Annexures To The Report

  • Annexure A — Certificate Of Approval As A Department Of Employment And Labour Approved Inspection Authority
  • Annexure B — SAIOH Certificates Of Surveyor And Technical Signatory
  • Annexure C — Equipment Calibration Certificates
  • Annexure D — Raw Measurement Data
  • Annexure E — Photo Log
  • Annexure F — Site And Floor Plans

The Safety Network (Africa) (Pty) Ltd

T/A SafeNet Africa

Dept. of Employment and Labour: AIA OH 0242 CI062

Signature of Technical Signatory

Riaan de Villiers

Signature of Surveyor

—